Disclosure: This post contains affiliate links and I will be compensated if you make a purchase after clicking through my links. Learn More
What is an 8010 welding rod used for? It is used for stick welding high-strength steel pipe, mostly cross-country oil and gas pipelines and in-plant process piping. The common version, AWS A5.5 E8010-P1, is a cellulosic, DC+ rod made to run vertical down on the hot pass, fill and cap.
Pipeline crews reach for it when the pipe is stronger than an E6010 deposit can match. It gives an 80 ksi minimum tensile strength with the same deep, digging arc pipe welders know from 6010.
The right 8010 rod depends on the pipe grade, the pass and your machine. Every spec we list comes from the AWS classification or a maker’s data sheet.
What Is an 8010 Welding Rod Used For?
An 8010 welding rod is used to weld pipeline steel pipe in the field, with the welder running downhill around a fixed joint. It handles open root joints and the passes that follow on API 5L grade pipe up to about X70.
- Cross-country pipelines: oil and gas transmission lines welded in the 5G fixed position.
- In-plant pipe: process piping that calls for the same strength as the line pipe.
- Hot pass, fill and cap: the passes after the root on X60, X65 and X70 pipe.
- Root pass on strong pipe: Lincoln rates its Pipeliner 8P+ for root passes up to X80 grade.
- Sour gas service: Pipeliner 8P+ meets NACE MR0175 for sour gas lines.

Credit: www.youtube.com
What the 8010 Numbers Mean
Welding rod numbers follow the AWS pattern, so E8010-P1 reads left to right like any other stick electrode.
| Part | Meaning |
|---|---|
| E | Covered electrode for arc welding |
| 80 | 80 ksi (550 MPa) minimum tensile strength |
| 1 | All positions |
| 0 | High cellulose sodium coating, DC+ only |
| P1 | Pipeline electrode with a cellulose coating and a set chemistry |
You’ll also see E8010-G on boxes. The “G” means general, so the spec leaves some properties open. Many rods, Lincoln Pipeliner 8P+ among them, carry both E8010-G and E8010-P1 on one label.
Canada uses metric names. The CSA W48 version of E8010-P1 is E5510-P1.
E8010-P1 Strength and Chemistry
AWS A5.5 sets the minimums for the weld metal. Lincoln’s data sheet for Pipeliner 8P+ lists these figures.
| Property | E8010-P1 minimum | Pipeliner 8P+ typical (as welded) |
|---|---|---|
| Tensile strength | 80 ksi (550 MPa) | 82 to 98 ksi (560 to 680 MPa) |
| Yield strength | 67 ksi (460 MPa) | 67 to 81 ksi (460 to 560 MPa) |
| Elongation | 19% | 19 to 30% |
| Charpy V-notch | 20 ft-lbf at -20°F (27 J at -30°C) | 38 to 84 ft-lbf at -20°F |
The alloy that lifts the strength is mostly nickel. The P1 class allows up to 1.00% nickel, with caps of 1.20% manganese, 0.50% molybdenum and 0.20% carbon.
8010 Rod Amperage and Polarity
Run E8010-P1 on DCEP (DC+). AC and DCEN give an unstable arc with this cellulosic coating, so an AC-only stick welder is a poor match.
| Rod diameter | Lincoln Pipeliner 8P+ range (DC+) |
|---|---|
| 1/8 in (3.2 mm) | 65 to 120 A |
| 5/32 in (4.0 mm) | 100 to 165 A |
| 3/16 in (5.0 mm) | 130 to 210 A |
Other brands publish slightly different ranges, so start with the chart on your rod can. Preheat may be needed on hardenable steels and heavy sections, per ESAB’s guidance for Sureweld 810P.
Common E8010-P1 Rods and Pipe Grades
Makers rate each rod for specific pipe grades. Check the rating against your welding procedure before you buy.
| Rod | Classification | Pipe grades listed |
|---|---|---|
| Lincoln Pipeliner 8P+ | E8010-P1, E8010-G | Root up to X80; hot, fill and cap up to X70 |
| ESAB Sureweld 810P | E8010-P1 | X60, X65 and X70 |

Credit: www.youtube.com
8010 vs 6010 vs 7018
All three are common stick rods, but they fill different jobs. Shop welders usually pick between 6010 vs 6011 vs 7018, and E8010-P1 adds a stronger option for pipe.
| Feature | E6010 | E8010-P1 | E7018 |
|---|---|---|---|
| AWS spec | A5.1 | A5.5 | A5.1 |
| Minimum tensile | 60 ksi | 80 ksi | 70 ksi |
| Coating | High cellulose sodium | High cellulose sodium | Low hydrogen, iron powder |
| Typical pipeline role | Root pass | Hot pass, fill, cap | Uphill fill and cap |
A common downhill sequence is an E6010 root, then E8010-P1 for the rest. The 8010 brings the strength the pipe needs, and the 6010 root is cheap and easy to control.
E8010-P1 is a cellulosic rod, so it is not a low-hydrogen electrode. Jobs that call for low-hydrogen weld metal need an EXX18-type rod instead.
Safety Note
Cellulosic rods make a lot of smoke and spatter. Weld with fume extraction or a respirator, wear a shade 10 or darker lens for stick work, and keep your gloves and gear dry to cut shock risk in wet field conditions.
Frequently Asked Questions
Can you weld uphill with 8010 rod?
Yes. E8010-P1 is an all-position rod, and ESAB lists both vertical-up and vertical-down for Sureweld 810P. Most pipeline procedures run it downhill, because that is the fast way to weld fixed pipe. Follow the position and travel direction your welding procedure names.
Is 8010 rod stronger than 6010?
Yes. E8010-P1 has an 80 ksi minimum tensile strength, and E6010 has 60 ksi. Both have a cellulosic coating and run on DC+, so the arc feels similar. The extra strength comes from alloying, mostly up to 1.00% nickel in the weld metal.
Can you run 8010 on an AC welder?
No, not well. E8010-P1 has a high cellulose sodium coating that needs DCEP (DC+). On AC or DCEN the arc becomes unstable and hard to control. Use a DC stick machine or an engine drive set to DC+ for this rod.
What does the P1 mean on 8010 rod?
P1 stands for a pipeline electrode with a cellulose coating under AWS A5.5. It also sets the weld metal chemistry, with limits on nickel, manganese, molybdenum and carbon. A rod labeled E8010-G has looser rules, and many brands certify one rod to both classes.
What amperage should I use for 5/32 8010 rod?
Lincoln lists 100 to 165 amps on DC+ for 5/32 in Pipeliner 8P+. Start near the middle of that range and adjust for pass type and position. Hot passes and caps may need different settings. Always check the chart printed on your rod can first.
Final Words
An 8010 welding rod is a pipeline rod. It brings 80 ksi strength to the hot pass, fill and cap on X60 to X70 pipe, and some brands rate it for root passes on stronger pipe.
Run it on DC+, start inside the amperage range on your can, and match the rod’s pipe grade rating to your procedure. For shop work on mild steel, E6010 or E7018 is usually the better pick.