How to Identify a Low Hydrogen Electrode

Disclosure: This post contains affiliate links and I will be compensated if you make a purchase after clicking through my links. Learn More

To learn how to identify a low hydrogen electrode, read the AWS number printed on the rod coating. A rod ending in 15, 16, 18, 28 or 48, such as E7018, is a low hydrogen class, and an H4, H8 or H16 suffix confirms the hydrogen limit.

The check takes under a minute once you know where to look. You need the rod itself, the can label and a little code reading.

Getting it right matters on code work. Moisture in the coating can cause porosity and other weld defects, so inspectors and procedures often call for a specific low hydrogen class.

Time: 1 to 2 minutes | Difficulty: Easy | Tools: the electrode, its can or box label, good light

What You’ll Need

  • The electrode you want to check, with the imprint near the bare grip end readable
  • The can, tube or box label the rods came in
  • The manufacturer’s data sheet if the label is gone
  • Your welding procedure, so you know which class and H level it calls for

How to Identify a Low Hydrogen Electrode: Step by Step

Work from the rod’s printed code first, then confirm on the label. The suffixes must be printed on the electrode itself, so the rod is always the best evidence.

Step 1: Find the AWS Number on the Coating

Look near the grip end of the rod for a printed code like E7018 or E7016. Welding rod numbers follow the AWS pattern: “E” for electrode, then strength, position and coating digits.

Step 2: Check the Last Two Digits

Lincoln Electric lists EXX15, EXX16, EXX18, EXX18-X, EXX28 and EXX48 as low hydrogen classes. The “XX” is the strength, so E7018 and E8018 both qualify.

EndingExampleLow hydrogen class?
15E7015Yes
16E7016Yes
18E7018, E8018Yes
28E7028Yes
48E7048Yes
10, 11, 13E6010, E6011, E6013Not on the low hydrogen list
Close look at the E7018 code printed on a low hydrogen welding rod

Credit: www.youtube.com

Step 3: Read the H Designator

An H number after the class shows the maximum diffusible hydrogen in milliliters per 100 grams of weld metal. Lincoln defines low hydrogen as less than 16 ml per 100 g.

DesignatorMax diffusible hydrogen
H1616 ml per 100 g of weld metal
H88 ml per 100 g of weld metal
H44 ml per 100 g of weld metal

Lower is drier. The Fabricator notes H4 is the value industry references most often.

Step 4: Look for the R Suffix

An “R” means moisture resistant. The rods passed a test of 9 hours at 80°F and 80% relative humidity with no more than 0.4% moisture in the coating afterward.

Lincoln says a standard low hydrogen coating is affected by moisture in about 2 hours, but a moisture-resistant coating can stay usable for up to 10 hours. Lincoln Excalibur 7018 MR, for example, is classed E7018 H4R.

Step 5: Check for a -1 Suffix

A “-1” after the class, as in E7018-1, means the rod meets requirements for improved toughness. It is still a low hydrogen rod, with a stricter impact rating.

Step 6: Confirm on the Can Label and Packaging

The label should repeat the full class, such as AWS E7018 H4R. Products such as H4 electrodes usually ship in a hermetically sealed can, which keeps the coating dry until you open it.

Once opened, keep the rods in a rod oven until use. Rods left out in high humidity may no longer meet their H rating.

Wet and dry 7018 low hydrogen electrodes compared next to a rod oven

Credit: www.youtube.com

Common Mistakes to Avoid

  • Judging by coating color: color is not part of the AWS code. Read the printed class instead.
  • Ignoring the suffix: an E7018 H4R and a plain E7018 share a class, but the H and R ratings differ.
  • Trusting rods from an open can: a low hydrogen rod left in humid air may not meet its rating anymore.
  • Guessing re-dry settings: re-dry only per the electrode maker’s instructions.
  • Mixing loose rods: keep each class in its own labeled oven or tube so you never weld with an unknown rod.

Polarity Clues for Low Hydrogen Rods

Lincoln says low hydrogen rods ideally run on DCEP, especially at 5/32 in and smaller, and many also run on AC. Some EXX18 rods are made for AC.

E7018 rods have a high iron powder content. Lincoln describes their arc as smoother and quieter with very low spatter, which is a handy clue, but the printed code is still the proof.

Frequently Asked Questions

Is 7018 a low hydrogen rod?

Yes. E7018 is the most common low hydrogen stick electrode. The “18” ending puts it in a low hydrogen class with high iron powder in the coating. Many E7018 rods also carry an H4 or H8 suffix and an R suffix for moisture resistance.

What does H4R mean on a welding rod?

H4 means the weld metal holds no more than 4 ml of diffusible hydrogen per 100 grams. R means the coating passed a moisture test of 9 hours at 80°F and 80% humidity. The base class, such as E7018, stays the same.

Is 6013 a low hydrogen electrode?

No. E6013 is not on the low hydrogen list, which covers EXX15, EXX16, EXX18, EXX28 and EXX48 rods. E6010 and E6011 are not on it either. Use a low hydrogen class like E7018 when your procedure or code calls for one.

How long can low hydrogen rods stay out of the oven?

Lincoln says a standard low hydrogen coating is affected by moisture in about 2 hours. A moisture-resistant R rod can be safe for up to 10 hours. Your welding code or procedure may set a shorter limit, so follow it first.

Can you tell a low hydrogen rod by its color?

No, not reliably. Coating color is not part of the AWS classification, and it varies by brand. Read the class printed near the grip end instead. Lincoln notes the H and R suffixes must be printed on the electrode and on the label.

Final Words

A low hydrogen electrode is easy to spot once you read the code. Look for an ending of 15, 16, 18, 28 or 48, then check the H number and any R or -1 suffix.

Confirm it on the can label, keep opened rods in an oven, and match the class to your procedure. When the print is worn off, treat the rod as unknown and set it aside.

Scroll to Top