Disclosure: This post contains affiliate links and I will be compensated if you make a purchase after clicking through my links. Learn More
Welding with 7018 rods is common in many industries, from construction to shipbuilding. People choose this rod for its strength, smooth arc, and low hydrogen content. But even experienced welders sometimes face a problem: porosity in their welds. Porosity creates small holes or cavities in the weld metal. These holes weaken the joint and can lead to failures. Many wonder why this happens, especially when using a trusted rod like the 7018.
This article explains why 7018 rods produce porosity. It covers all possible causes, from the rod itself to welding technique and environmental factors. If you want to understand and prevent porosity, this guide will give you clear answers, practical advice, and real examples.
What Is Porosity In Welding?
Porosity means there are tiny holes inside the weld. These holes may be too small to see but can grow bigger and weaken the weld. The holes form when gas gets trapped in the melted metal and cannot escape before the weld solidifies.
Types Of Porosity
- Surface Porosity: Small holes on the surface of the weld bead.
- Subsurface Porosity: Holes found below the surface, often discovered only with X-rays or ultrasonic testing.
- Cluster Porosity: Groups of small holes close together.
- Linear Porosity: Holes that form in a line, usually along the weld.
Why Is 7018 Rod Popular?
Many welders use 7018 rods for critical work because they provide:
- Low hydrogen, which reduces the risk of cracking.
- Strong, smooth welds.
- Good results with both AC and DC welding machines.
But even with these benefits, porosity can still occur.

Credit: www.reddit.com
How Does A 7018 Rod Work?
The 7018 rod has a steel core with a special coating. This coating contains iron powder and low-hydrogen compounds. When the rod melts, the coating creates a shield of gas and slag. This shield protects the weld from the air, keeping hydrogen and other gases out.
But if something interrupts this shield, gases can enter the weld and create porosity.
Main Causes Of Porosity With 7018 Rod
Many factors can cause porosity. Below are the main causes, each explained in detail.
1. Moisture In The Electrode
7018 rods are sensitive to moisture. The coating absorbs water from the air, especially if stored in a humid place. When you use a damp rod, the water turns into steam during welding. Steam is a gas, and it gets trapped in the weld as porosity.
Key facts:
- Even a small amount of moisture can cause many holes.
- Damp rods are the most common cause of porosity with 7018.
Prevention tips:
- Store rods in a rod oven at 120°C–150°C (250°F–300°F).
- Use rods soon after opening a new box.
- Never use rods that have been left out overnight in a humid shop.
2. Contaminated Base Metal
If the metal you are welding is dirty, porosity can form. Common contaminants include:
- Oil: Leaves carbon and hydrogen when burned.
- Grease: Similar to oil, but thicker and harder to remove.
- Paint: Contains chemicals that release gas when heated.
- Rust: Traps moisture and breaks down into gases during welding.
- Mill Scale: The dark layer on steel from the rolling process; it can trap gases.
Even if you use a perfect rod and technique, dirty metal will almost always produce porosity.
Prevention tips:
- Clean the weld area with a wire brush or grinder.
- Wipe with a solvent for oil or grease.
- Remove rust and paint completely.
3. Poor Welding Technique
Your technique matters. Common mistakes that cause porosity include:
- Incorrect Angle: Holding the rod too flat or too steep changes the gas shield.
- Fast Travel Speed: Moving too quickly does not allow gas to escape.
- Long Arc Length: Holding the rod too far from the workpiece exposes the weld to air.
- Poor Rod Manipulation: Not weaving or pausing as needed can trap gases.
Small changes in how you weld can make a big difference.
4. Wind Or Air Currents
The gas shield around the weld is sensitive to wind. Even a gentle breeze can blow away this shield, letting air into the weld. This is a common problem when welding outdoors or near large fans.
Prevention tips:
- Weld indoors or block the wind when possible.
- Use welding curtains to protect your work area.
5. Wrong Machine Settings
The wrong current or voltage can create an unstable arc. This leads to:
- Spatter: Tiny drops of molten metal that trap air.
- Inconsistent Shield: Makes it easier for air to reach the weld pool.
7018 rods usually work best at 90–130 amps for 3.2 mm (1/8 inch) rods, but always check the manufacturer’s guide.
6. Defective Or Damaged Rods
Rods can be damaged during shipping or storage. Common problems:
- Cracked coating lets air in.
- Chipped ends expose the core.
- Old rods lose their protective properties.
Never use rods that look damaged or very old.
7. Incorrect Polarity
7018 rods require the right polarity for stable arc and good shielding. Most require DCEP (Direct Current Electrode Positive), but some can use AC. Using the wrong polarity can reduce the quality of the shield, causing porosity.
8. Contaminated Shielding Gas
While 7018 rods do not use external gas, sometimes welders use a combination of processes or switch between rods and MIG/TIG. If shielding gas is contaminated with moisture or air, it can cause porosity, especially if equipment shares hoses or lines.
9. Base Metal Composition
Some metals contain elements that react during welding. High sulfur or phosphorus in steel can create gases in the weld pool. Old or recycled steel may have unknown elements that contribute to porosity.
10. Joint Design Issues
Tight joints or poor fit-up can trap air or gas in the weld area. If the weld cannot flow smoothly, gas bubbles may not escape before the metal solidifies.
11. Slag Inclusion
Slag is the protective layer that forms on top of the weld. If slag from a previous pass is not removed, new weld metal can trap gases against it, causing porosity.
12. Low-quality Rods
Cheap or imitation 7018 rods may have poor-quality coating. This coating may not provide enough protection, or it may absorb moisture more easily, leading to porosity.
13. High Humidity In The Welding Area
Welding in a very humid environment increases the risk of moisture entering the weld pool, either from the rod, the base metal, or the air itself.
14. Welding Over Previously Porous Welds
If you weld over a bead that already has porosity, the problem can get worse. Gas pockets may expand or connect, causing larger holes.
15. Incorrect Storage Of Rods
Leaving rods in open air, or moving them between hot and cold rooms, can cause condensation and moisture pickup. Proper storage is critical.
16. Arc Blow
Arc blow is a magnetic effect that pushes the arc out of position. This can cause uneven heating and reduce shielding, leading to porosity.
17. Using Wet Gloves Or Tools
Wet gloves or tools can introduce extra moisture near the weld, which may get trapped in the weld pool.
18. Poor Ground Connection
A bad ground connection causes an unstable arc. This instability can affect the gas shield and lead to porosity.
19. Overheating The Rod
If you weld at too high an amperage, the rod’s coating can burn away before it protects the weld, exposing the pool to air.
20. Multiple Passes Without Cleaning
If you make several weld passes without cleaning between them, old slag, contaminants, or moisture can be trapped in the new weld.
21. Using The Wrong Rod Size
A rod that is too large for the joint may not allow gas to escape, while a rod that is too small may not provide enough shielding.
22. Improper Handling During Welding
Dropping the rod, dragging it on the ground, or striking it too hard can damage the coating and let air reach the weld pool.
23. Poor Fit-up And Gaps
Gaps or poor fit can create pockets where gas collects, especially in root passes or tight corners.
24. High Welding Speed
Welding too fast gives gas less time to escape, making porosity more likely.
25. Poor Quality Control In Manufacturing
Some rods may leave the factory with defects in the coating or core, leading to porosity even when stored and used correctly.
How To Identify Porosity In Welds
Porosity may not always be visible. Here are ways to check:
- Visual Inspection: Look for small holes or rough areas on the weld bead.
- X-Ray or Ultrasonic Testing: Used on critical welds to find hidden porosity.
- Break Tests: Bend or break test samples to see inside the weld.
- Etching: Apply acid to expose holes in cross-sections.
Porosity looks like small craters or bubbles. If you see these, you need to find the cause before continuing.
Effects Of Porosity In 7018 Welds
Porosity weakens welds in several ways:
- Reduced Strength: Holes act as stress points.
- Poor Appearance: Visible holes look unprofessional.
- Leaking Joints: In tanks or pipes, porosity can cause leaks.
- Failed Inspections: Many codes do not allow any porosity in critical welds.
- Cracking: Holes can connect and grow, leading to cracks.
How To Prevent Porosity With 7018 Rods
You can avoid porosity by following best practices:
- Store rods in a dry, heated oven.
- Clean the base metal before welding.
- Use the correct welding technique and rod angle.
- Avoid welding in wind; use curtains if outdoors.
- Set the machine correctly for the rod size.
- Inspect rods before use for cracks or damage.
- Clean between passes if making multiple layers.
- Check the joint fit-up.
- Replace damaged or low-quality rods.
- Maintain good grounding and connections.
The Science Behind 7018 Rod Porosity
Understanding the science helps you prevent problems.
- The rod’s coating forms a barrier of carbon dioxide and slag.
- If this barrier is broken (by wind, long arc, or poor coating), oxygen and nitrogen from the air enter the weld.
- These gases do not mix well with molten steel. They form bubbles as the metal cools.
- Water from moisture creates hydrogen gas, which is even more likely to cause porosity and cracking.
7018 rods are low-hydrogen because hydrogen is the most dangerous gas for welds. But if you let hydrogen in, the rod’s design cannot protect the weld.
Data: 7018 Rod Vs. Other Electrodes (porosity Risk)
Here’s a comparison of common welding rods and their risk of porosity if used incorrectly:
| Rod Type | Hydrogen Risk | Porosity Sensitivity | Best Use |
|---|---|---|---|
| 7018 | Low | High if wet | Structural steel |
| 6010 | High | Medium | Pipelines, repairs |
| 6013 | Medium | Medium | Sheet metal |
| 7024 | Low | Low | Flat welds |
Common Myths About 7018 Rod Porosity
Many people believe some myths about porosity:
- “7018 rods are always low-hydrogen.” Only if kept dry.
- “A little rust won’t hurt.” Even small amounts can cause problems.
- “You can dry wet rods with a torch.” This damages the coating instead of drying it.
- “Porosity is just a cosmetic problem.” It weakens the weld and can cause failure.
Credit: www.everlastgenerators.com
What Most Beginners Miss
Two important facts are often overlooked:
- Moisture can come from anywhere: Even sweat from your gloves or moisture in the air can enter the weld if you are not careful.
- Porosity can be hidden: Just because you do not see holes does not mean the weld is solid. Internal porosity is a silent problem.
Practical Example
A welder in a shipyard used 7018 rods that were left on a workbench overnight. The next day, several welds failed ultrasonic inspection. The cause was moisture picked up from the humid air at night. After switching to fresh rods from a rod oven, the problem disappeared.

Credit: www.reddit.com
Table: Best Practices For 7018 Rod Storage
| Storage Method | Risk of Porosity | Recommended? |
|---|---|---|
| Rod oven (120°C–150°C) | Very Low | Yes |
| Sealed package, unopened | Low | Yes |
| Open air, dry room | Medium | No |
| Open air, humid room | High | No |
How To Fix Porosity In 7018 Welds
If you find porosity:
- Grind out the defective weld down to solid metal.
- Clean the area thoroughly.
- Use dry, high-quality rods.
- Adjust machine settings and technique.
- Weld again, checking the bead closely.
Never try to patch a porous weld. Always remove the bad section.
Advanced Prevention Tips
- Use a hygrometer to measure humidity in your storage area.
- Keep a log of rod batch numbers and storage times.
- Rotate rod stock so older rods are used first.
- Test new rods on scrap before starting critical welds.
- Keep welding cables and machine connections clean and tight.
Table: Welding Parameters For 7018 Rod (1/8 Inch)
| Amperage | Polarity | Travel Speed | Arc Length |
|---|---|---|---|
| 90–130A | DCEP or AC | Moderate | Short (1/8″) |
Summary
Porosity with 7018 rods comes from moisture, poor technique, dirty metal, or environmental issues. Even though these rods are designed to prevent hydrogen problems, they are sensitive to how you store and use them. Always keep rods dry, clean your work, and use the right settings to avoid porosity.
If you follow best practices, you can produce strong, clean welds with 7018 rods. If you have problems, check each possible cause listed above and fix it before continuing.
For further reading on welding safety and rod storage, see this Wikipedia article.
Frequently Asked Questions
Why Does Moisture Cause Porosity With 7018 Rods?
Moisture in the rod’s coating turns to steam when heated. This steam becomes gas, which gets trapped in the weld as small holes or cavities.
How Can I Store 7018 Rods To Prevent Porosity?
Keep rods in a rod oven at 120°C–150°C or in a sealed package until ready to use. Avoid storing them in humid or damp places.
Can I Use 7018 Rods After They Get Wet?
No. Once wet, 7018 rods can cause serious porosity. You must dry them in a rod oven, but it is best to use fresh rods.
Does Cleaning The Base Metal Really Matter?
Yes. Oil, paint, rust, and other contaminants release gases when heated, which cause porosity. Always clean the weld area well.
What Is The Best Way To Check For Porosity In A Weld?
Look for small holes on the surface, but also use X-ray or ultrasonic testing for critical welds, since porosity can be hidden inside the metal.
With this knowledge, you can prevent porosity and get the best results from your 7018 rods every time you weld.